9
Benefits

Home | Sitemap 

AKTS Software
Online Shop
AKTS-Thermokinetics
Download demo
E-Learning
Help Thermokinetics
Technical comments
Get more information
AKTS-Thermal Safety
Download demo
E-Learning
Help Thermal Safety
Technical comments
     > DSC - C80 - TMRad
     > DSC - SADT
     > DSC - HFC
     > DSC - Cookoff
Get more information
AKTS-SML Diffusion
Download demo
Live video
Help SML
Exposure and Compliance
Migration modelling
Legal background
Technical comments
Get more information
AKTS-Calisto
Overview
Help Calisto
Get more information
About us
Overview
Expert solutions
Information
Contact us
Order a brochure
Partners
Setaram
SWISSI OFSP
 armasuisse
 Logo ACL Instruments

   AKTS AG
TechnoArk 3
3960 Siders
Switzerland


Customer service:
Phone:+41-848-800221
Fax:+41-848-800222
 

 

Technical comments

ADVANCED KINETICS-BASED SIMULATION OF TIME TO MAXIMUM RATE UNDER ADIABATIC CONDITIONS

B. Roduit1*, W. Dermaut2, A. Lunghi3, P. Folly4, B. Berger4, A. Sarbach4


1 AKTS AG Advanced Kinetics and Technology Solutions, http://www.akts.com, TECHNOArk 3, 3960 Siders, Switzerland
2 Janssen Pharmaceutica NV, http://www.jnj.com, 2340 Beerse, Belgium
3 Stazione Sperimentale per i Combustibili, http://www.ssc.it/, 20097 San Donato Milanese, Italy
4armasuisse, Science and Technology, http://www.armasuisse.ch, 3602 Thun, Switzerland


Abstract

An adiabatic calorimeter is very often used for the investigation of runaway of exothermic reactions. However the ideal adiabatic environment is a theoretical state which during laboratory scale testing cannot be obtained but may only be approached. Deviation from the fully adiabatic state comes from (i) the thermal inertia of the test system or heat lost into the sample container and (ii) the loss of heat from the container itself to the environment that reflects the ‘operational adiabaticity' of the instrument. In addition to adiabatic testing, advanced kinetic approach based on the kinetic parameters determined from DSC data performed under different heating rates can be applied. It enables to simulate what may happen on a large scale by testing and up-scaling results obtained with a small amount of the sample.
The present study describes the method of the evaluation of kinetic parameters of the coupling reaction of aniline with cyanamide in water HCl from the DSC signals measured in non-isothermal experiments carried out with the rates of 0.5-8 K/min. The reaction rate and reaction progress in adiabatic conditions were predicted after introducing the kinetic description of the reaction into the heat balance equations. It enabled to calculate the thermal safety diagram depicting the runaway time as a function of the process temperature. The influence of thermal inertia of the system, expressed by the F-factor, on the reaction course in concentrated and diluted reactant solutions was determined and discussed.

Keywords: thermal decomposition kinetics, DSC, time to maximum rate (TMR), adiabatic conditions, thermal runaway, F-factor, aniline, cyanamide

Journal of Thermal Analysis and Calorimetry, Vol. 93 (2008) 1, 163–173. If your institution has access, you may view this paper at:
http://dx.doi.org/10.1007/s10973-007-8866-1
(you may need to copy and paste the URL into your browser).

 

 